Guide · K-factor
K-factor for sheet metal bending
What the K-factor means, how it relates to DIN 6935, and how to derive your own value from a test bend.
What is the K-factor?
The K-factor locates the neutral axis inside the bend: K = t/s, where t is the distance from the inside surface to the neutral axis and s is the material thickness. K = 0.5 means mid-thickness; smaller values mean the neutral axis has shifted toward the inside, which happens with tight radii relative to thickness. Valid range: 0 < K ≤ 0.5.
The German standard DIN 6935 uses a correction factor k referenced to half the thickness. The two are directly related: k = 2 · K.
Formulas
K-factor: K = k / 2 = 0.325 + 0.25 · log₁₀(Rᵢ / s)
Bend allowance BA = π · α/180° · (Rᵢ + K · s)
K from a test bend: K = (BA · 180° / (π · α) − Rᵢ) / s
K-factor chart per DIN 6935
| Rᵢ/s | 0.25 | 0.5 | 0.75 | 1 | 1.5 | 2 | 3 | 4 | 5 |
|---|---|---|---|---|---|---|---|---|---|
| k (DIN 6935) | 0.349 | 0.499 | 0.588 | 0.650 | 0.738 | 0.801 | 0.889 | 0.951 | 0.999 |
| K = k/2 | 0.174 | 0.250 | 0.294 | 0.325 | 0.369 | 0.400 | 0.444 | 0.476 | 0.500 |
Rule-of-thumb values (air bending)
Widely used shop values, often higher than DIN 6935. Use them as a starting point, not as a replacement for a test bend:
| Inside radius | Aluminium (soft) | Mild steel | Stainless steel |
|---|---|---|---|
| Rᵢ < s | 0.33 | 0.38 | 0.40 |
| s ≤ Rᵢ ≤ 3 · s | 0.40 | 0.43 | 0.45 |
| Rᵢ > 3 · s | 0.50 | 0.50 | 0.50 |
Example: find your K-factor from a test bend
Test strip s = 2 mm, measured inside radius Rᵢ = 2 mm, 90° bend, target outside dimensions 50 × 100 mm. The strip that produced exactly these dimensions was 146.40 mm long.
BA = 146.40 − 142 = 4.40 mm
K = (4.40 · 180 / (π · 90) − 2) / 2 = 0.40 → enter as custom K-factor in BendUnfold
For comparison, DIN 6935 gives K = 0.325 at Rᵢ/s = 1 and a 146.16 mm blank. The 0.24 mm difference is why a measured value matters for production parts.
In the app
BendUnfold calculates per DIN 6935 by default and shows the k value it used. In K-factor mode you enter your own value (0 < K ≤ 0.5), for example for aluminium, stainless steel or a specific punch/die combination. Flat length, bend lines and DXF update instantly.
FAQ
What is the K-factor in sheet metal bending?
The K-factor is the position of the neutral axis as a fraction of material thickness, measured from the inside of the bend. It ranges from 0 to 0.5 and is used in the bend allowance formula BA = π · α/180 · (Rᵢ + K · s).
What K-factor should I use for steel, stainless and aluminium?
As a starting point for Rᵢ between s and 3 · s in air bending: mild steel about 0.43, stainless about 0.45, soft aluminium about 0.40. DIN 6935 gives 0.33 to 0.5 for steel depending on Rᵢ/s. Verify with a test bend for production parts.
How is the K-factor related to DIN 6935?
DIN 6935 uses the correction factor k = 0.65 + 0.5 · log₁₀(Rᵢ/s), referenced to half the thickness. K = k/2, so at Rᵢ = s, k = 0.65 and K = 0.325.
How do I calculate the K-factor from a test piece?
Bend a strip of known length, measure the outside dimensions, compute the bend allowance as blank length minus the straight flange portions, then solve K = (BA · 180/(π · α) − Rᵢ)/s.
Is there an app that calculates flat patterns with a custom K-factor?
Yes. BendUnfold for iPhone and iPad calculates flat patterns per DIN 6935 or a custom K-factor and outputs flat length, backgauge bend lines and a 1:1 DXF.