BendUnfold app icon BendUnfold

Guide · K-factor

K-factor for sheet metal bending

What the K-factor means, how it relates to DIN 6935, and how to derive your own value from a test bend.

What is the K-factor?

The K-factor locates the neutral axis inside the bend: K = t/s, where t is the distance from the inside surface to the neutral axis and s is the material thickness. K = 0.5 means mid-thickness; smaller values mean the neutral axis has shifted toward the inside, which happens with tight radii relative to thickness. Valid range: 0 < K ≤ 0.5.

The German standard DIN 6935 uses a correction factor k referenced to half the thickness. The two are directly related: k = 2 · K.

Formulas

DIN 6935:  k = 0.65 + 0.5 · log₁₀(Rᵢ / s), limited to 0 … 1
K-factor:  K = k / 2 = 0.325 + 0.25 · log₁₀(Rᵢ / s)
Bend allowance BA = π · α/180° · (Rᵢ + K · s)
K from a test bend:  K = (BA · 180° / (π · α) − Rᵢ) / s

K-factor chart per DIN 6935

Rᵢ/s0.250.50.7511.52345
k (DIN 6935)0.3490.4990.5880.6500.7380.8010.8890.9510.999
K = k/20.1740.2500.2940.3250.3690.4000.4440.4760.500

Rule-of-thumb values (air bending)

Widely used shop values, often higher than DIN 6935. Use them as a starting point, not as a replacement for a test bend:

Inside radiusAluminium (soft)Mild steelStainless steel
Rᵢ < s0.330.380.40
s ≤ Rᵢ ≤ 3 · s0.400.430.45
Rᵢ > 3 · s0.500.500.50

Example: find your K-factor from a test bend

Test strip s = 2 mm, measured inside radius Rᵢ = 2 mm, 90° bend, target outside dimensions 50 × 100 mm. The strip that produced exactly these dimensions was 146.40 mm long.

Straight portions: (50 − Rᵢ − s) + (100 − Rᵢ − s) = 46 + 96 = 142 mm
BA = 146.40 − 142 = 4.40 mm
K = (4.40 · 180 / (π · 90) − 2) / 2 = 0.40  → enter as custom K-factor in BendUnfold

For comparison, DIN 6935 gives K = 0.325 at Rᵢ/s = 1 and a 146.16 mm blank. The 0.24 mm difference is why a measured value matters for production parts.

In the app

BendUnfold calculates per DIN 6935 by default and shows the k value it used. In K-factor mode you enter your own value (0 < K ≤ 0.5), for example for aluminium, stainless steel or a specific punch/die combination. Flat length, bend lines and DXF update instantly.

FAQ

What is the K-factor in sheet metal bending?

The K-factor is the position of the neutral axis as a fraction of material thickness, measured from the inside of the bend. It ranges from 0 to 0.5 and is used in the bend allowance formula BA = π · α/180 · (Rᵢ + K · s).

What K-factor should I use for steel, stainless and aluminium?

As a starting point for Rᵢ between s and 3 · s in air bending: mild steel about 0.43, stainless about 0.45, soft aluminium about 0.40. DIN 6935 gives 0.33 to 0.5 for steel depending on Rᵢ/s. Verify with a test bend for production parts.

How is the K-factor related to DIN 6935?

DIN 6935 uses the correction factor k = 0.65 + 0.5 · log₁₀(Rᵢ/s), referenced to half the thickness. K = k/2, so at Rᵢ = s, k = 0.65 and K = 0.325.

How do I calculate the K-factor from a test piece?

Bend a strip of known length, measure the outside dimensions, compute the bend allowance as blank length minus the straight flange portions, then solve K = (BA · 180/(π · α) − Rᵢ)/s.

Is there an app that calculates flat patterns with a custom K-factor?

Yes. BendUnfold for iPhone and iPad calculates flat patterns per DIN 6935 or a custom K-factor and outputs flat length, backgauge bend lines and a 1:1 DXF.